SPLICE & MISSING PLY DETECTOR SPECIFICATIONS |
|
|
Defects Types Detected: |
Splices Missing Plies Web Breaks |
|
Material Compatibility: |
Papers Plastics Films Other Non-metallic Materials |
|
Web Thickness: |
0.20" Max. (5.08 mm Max.) |
| Gap Width: | 0.25" (6.35 mm) |
|
Maximum Web Speed: |
10,000 fpm (3,048 m/min) |
|
Relay Alarm Outputs: Dry Output Contact Closures: Current Capacity at 110 VAC: Current Capacity at 220 VAC: Alarm On Period:
|
2 (Non-inductive) 0.1 Amp 0.05 Amp 1 Second |
|
Electronic Alarm Output: Pulse Outputs: Voltage: Direction: Duration:
|
1 15 V (± 3 V) Positive Going 10 ms |
|
Ambient Temperature: |
40 to 160° F (4 to 70° C) |
|
Dimensions: |
6.0" X 7.5" X 4.37" (15.24 cm X 19.05 cm x 11.1 cm) |
|
Power: |
110/220/240 VAC 50/60 Hz Single Phase |
|
Specifications are subject to change without notice. Note: If you web speed is less than 100 fpm, specialized circuitry may have to be applied. If you purchase this unit and it is found that specialized circuitry is required due to misinformation, all monies applicable will be charged, then applied as a credit for replacement of this standard unit with a specialized unit. Additional fees may be applied. |
|